CARACTERISTICAS Y DETALLES TECNICOS :
PINZA AMPERIMETRICA MARCA: AMPROBE MODELO:
ACD-16 TRMS PROGENERAL SPECIFICATIONS
Relative Humidity: Maximum relative humidity
80% for temperature up to 31ËšC decreasing linearly to 50% relative humidity at 40ËšC
Altitude: Operating below 2000m
Storage Temperature: -20ËšC to 60ËšC, < 80%
R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x (specified accuracy)/ oC @(0ËšC -18ËšC or 28ËšC -40ËšC),
or otherwise specified
Sensing: Average sensing for model; True RMS
sensing for model
Safety: Meets IEC61010-2-032(1994),
EN61010-2 032(1995), UL3111-2-
032(1999).Category III 600 Volts AC & DC
Transient protection: 6.5kV (1.2/50µs surge)
for all models
Pollution degree: 2
E.M.C.: Meets EN61326(1997, 1998/A1),
EN61000-4-2(1995), and EN61000-4-3(1996)
In an RF field of 3V/m: Total Accuracy =
Specified Accuracy + 45 digits Performance
above 3V/m is not specified
Overload Protections :
ACA Clamp-on jaws: AC 1000A RMS continuous + & COM terminals (all functions):
600VDC/VAC RMS
Power Supply: standard 1.5V AAA Size (NEDA
24A or IEC LR03) battery X 2
Power Consumption:
Voltage & ACA functions: 3.5mA typical
Ohm & Temperature functions: 4mA typical
APO Timing: Idle for 16 minutes
APO Consumption: 10µA typical
Dimension: L224mm X W78mm X H40mm
Weight: 224 gm approx
Jaw opening & Conductor diameter: 45mm max
Special features: Display Backlight (ACD-16
TRMS) Auto-Hold; Display Hold; On screenstandalone Hi-Lo logging (5400 minutes) at sampling
speed of faster than: 20 per second for Voltage &
ACA functions 4 per second for Ohm & Temperature
functions 2 per second for Hz function
Accessories: Test leads (MTL-90B), batteries
installed, user's manual, TPK-59 banana plug
type-K thermocouple & soft carrying pouch
Optional accessories: RS-232 KIT2 interface kit.
Electrical Specifications: Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 ˚C ±5 ˚C & less than 75% R.H. True
RMS Models ACD-16TRMS ACV & ACA clamp-on
accuracies are specified from 5% to 100% of
range or otherwise specified. Maximum Crest
Factor are as specified below, & with frequency
spectrums, besides fundamentals, fall within the
meter specified AC bandwidth for non-sinusoidal
waveforms. Fundamentals are specified at 50Hzitem: sig – Pinza amperimetrica | pinza | Pinza digital | pinza portatil