AMPROBE ACDC-3400 IND

El precio original era: S/6.284,00.El precio actual es: S/3.145,00.

Stock Disponible10 Unidades Disponibles
+ -

AMPROBE ACDC-3400 IND STOCK DISPONIBLE
​


PINZA AMPERIMETRICA – > MARCA: AMPROBE -> MODELO: ACDC-3400 IND ; REALIZAMOS ENVIOS A TODO EL PERU AMPROBE ENTREGA INMEDIATA


ACDC-3400 IND
CAT IV Industrial True RMS
Clamp Meter
This CAT IV rated clamp is ideal for industrial applications and
utilities that require an extra level of safety. Includes True RMS
sensing for accuracy and dependability. Extra large jaw to
accommodate wide diameter wires.
ā–  True RMS
ā–  Measures AC Current up to 1000 ACA, Voltage up to 750
VAC / 1000 VDC, Frequency, Resistance and Capacitance
and Duty Cycle
ā–  Peak Hold
ā–  1000A DC Current
ā–  Relative Zero
ā–  Audible continuity
ā–  Auto and manual ranging
ā–  Auto power off
ā–  Data hold
ā–  Backlight
ā–  Diode Test
ā–  Duty Cycle
ā–  Accommodates conductors up to 2ā€ (51mm) in diameter
ā–  Safety CAT IV 600 V, CAT III 1000 V
ā–  Test leads, battery (installed), Users Manual, and Carrying
Case included with the product

ACDC-3400 IND CAT IV Industrial True RMS Clamp Meter Data Sheet
Specifications (valid for 23 °C ± 5 °C, for less than 75% relative humidity).
DC Volts Ranges Accuracy
660.0 mV, 6.600 V, 66.00 V, 660.0 V, 1000 V ± (0.5% rdg + 2 dgts)
Input impedance 660 mV: >100 MĪ©; 6.6 V:10 MĪ©; 66 V to 1000 V: 9.1 MĪ©
Overload protection 1000 VDC or 750 VAC rms
AC Volts True RMS Ranges Frequency Accuracy
660.0 mV 50 to 100 Hz ± (1.5% rdg + 8 dgts)
6.600V, 66.00V 50 to 500 Hz ± (1.5% rdg + 8 dgts)
660.0V, 750V 50 to 500 Hz ± (1.5% rdg + 8 dgts)
Frequency* 50 to 1 kHz ± (0.1% rdg + 5 dgts)
* Frequency: 10% to 100% of voltage range
Peak Hold Ranges Frequency Accuracy
66.00V, 660.0V, 750V 50 to 500 Hz ± (3.0% rdg + 300 dgts)
AC coupled TRMS 5% to 100% of range
Crest factor ≤ 3
Input impedance 660 mV: >100 MĪ©; 6.6 V:10 MĪ©; 66 V to 750 V: 9.1 MĪ©
Overload protection 1000 VDC or 750 VAC rms
AC Current True RMS Ranges Frequency Accuracy
660.0A 50 to 60 Hz ± (2.0% rdg + 10 dgts)
660.0A 61 to 400 Hz ± (3.0% rdg + 10 dgts)
1000 A 50 to 60 Hz ± (2.5% rdg + 10 dgts)
1000 A 61 to 400 Hz ± (3.5% rdg + 10 dgts)
Frequency* 50 to 1kHz ± (0.1% rdg + 5 dgts)
* Frequency: 10% to 100% of current range
Peak Hold Ranges Frequency Accuracy
660.0A, 1000A 50 to 400 Hz ± (3.0% rdg + 200 dgts)
AC coupled TRMS 5% to 100% of range
Crest factor ≤ 3
Overload protection 1000A AC
DC Current Range Accuracy
660.0A ± (2.0% rdg + 5 dgts)
1000A ± (3.0% rdg + 5 dgts)
Overload protection 1000A DC
Resistance Range Accuracy
660.0Ω, 6.600kΩ, 66.00kΩ, 660.0kΩ ± (1.0% rdg + 5 dgts)
6.600MΩ ± (2.0% rdg + 5 dgts)
66.00MΩ ± (3.5% rdg + 5 dgts)
Open circuit volts -0.8 Vdc typical , (-1.2 Vdc on 660 Ī© range)
Overload protection 1000 VDC or 750 VAC rms